Ravel RE 102 Conventional Fire Alarm Control Panel
Ravel RE 102 Conventional Fire Alarm Control Panel

Ravel RE 102 Conventional Fire Alarm Control Panel

MOQ : 1 Unit

Ravel RE 102 Conventional Fire Alarm Control Panel Specification

  • Alarm Density
  • One alarm per zone (multiple sensors per zone possible)
  • Suitable For
  • Small/medium residential, office, commercial premises
  • Sensor Life
  • Depends on detector type; typically 5-10 years
  • Sensor Cable
  • Suitable for 1.5 mm2 FRLS (max length per zone subject to voltage drop limits)
  • Wireless
  • No (fully wired system)
  • Wireless Distance
  • Not applicable (wired system)
  • Working Current
  • Up to 200mA (with active alarms)
  • Control Distance
  • As per wiring; each zone supports conventional wiring up to recommended limits
  • Alarm time
  • Continuous till reset
  • Voltage
  • 24V DC operating (from inbuilt SMPS)
  • Alarm startup time
  • <3 seconds (detection to indication)
  • Standby Current
  • <100mA (without alarm)
  • Sensor Type
  • Supports conventional smoke/heat detectors
  • Sensitivity
  • Based on detector specifications (panel monitors detectors)
  • Noise Level
  • Panel <30 dB (acoustic alarms external)
  • Power Supply
  • 230V AC 15%, 50 Hz
  • Alarm Light Color
  • Red (on panel indication)
  • Remote Control
  • No (Front panel operation only)
  • Detection Range
  • Depends on connected detectors, typically up to 100m per zone with standard detectors
  • Cable Entry
  • Knockouts provided for cable entry
  • Weight
  • Approx. 5 kg (without batteries)
  • Number of Zones
  • 2 zones
  • Dimensions
  • Approx. 330 x 260 x 100 mm
  • Operating Temperature
  • 0C to +50C
  • Battery Backup
  • Provision for 2 x 12V sealed lead acid batteries (up to 7 Ah)
  • Controls
  • Mute, Reset, Test, Lamp Test buttons
  • Panel Type
  • Conventional Fire Alarm Panel
  • Display
  • LED indications for alarm, fault, power
  • Output Relays
  • Common Alarm, Fault & Supervisory relay outputs
  • Enclosure
  • Metal cabinet, wall mount
  • Humidity
  • 0-95% RH (non-condensing)
  • Zone End of Line
  • 4k7 Ohm resistor
 

Ravel RE 102 Conventional Fire Alarm Control Panel Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

More Products in Fire Alarm System Category

Addressable Ravel Moniti NX Fire Alarm System

Addressable Ravel Moniti NX Fire Alarm System

Minimum Order Quantity : 1 Unit

Power Supply : 230V AC, 50Hz with backup battery support

Alarm startup time : < 5 seconds (to first notification)

Standby Current : Less than 200mA

Sensor Type : Addressable smoke, heat, multicriteria detectors

Alarm Light Color : Red (visual indicators on connected devices)

Avni Lcs Ravel Loop Card

Avni Lcs Ravel Loop Card

Minimum Order Quantity : 1 Unit

Power Supply : 12V DC

Alarm startup time : <1 second

Standby Current : <25mA

Sensor Type : Electronic Loop Sensor

Alarm Light Color : Red

Ravel 4 Zone Fire Alarm Panel

Ravel 4 Zone Fire Alarm Panel

Minimum Order Quantity : 1 Unit

Power Supply : 230V AC, 50Hz main supply

Alarm startup time : < 5 seconds

Standby Current : < 100mA (panel only)

Sensor Type : Compatible with conventional smoke & heat detectors

Alarm Light Color : Red (Panel LED indicators)