Fire Alarm System

Unlock the advantages of our Fire Alarm System, meticulously offered by our esteemed company as a service provider, supplier, and trader with over 8 years of industry expertise. Designed for wide-ranging applications, our peerless lineup features popular products such as the Ravel 4 Zone Fire Alarm Panel, Ravel RE 102 Conventional Fire Alarm Control Panel, Addressable Ravel Moniti NX Fire Alarm System, and Avni Lcs Ravel Loop Card. Purchase peace of mind with our Fire Alarm Systems, which boast superlative reliability, magnificent detection accuracy, swift alert response, top-notch integration with emergency protocols, and easy maintenance for ongoing performance. When compared to generic offerings, these systems stand out for their versatility and robust domestic supply ability across all of India. Choose our special Fire Alarm System solutions for guaranteed safety in diverse environments, benefitting from proven technology and incomparable support suited for every safety-conscious business.

Ravel 4 Zone Fire Alarm Panel

MOQ : 1 Unit

  • Alarm Density
  • N/A - depends on external detectors
  • Alarm Light Color
  • Red (Panel LED indicators)
  • Alarm startup time
  • < 5 seconds
  • Alarm time
  • Continuous until reset/silenced
  • Control Distance
  • Varies as per installation specifications
  • Detection Range
  • Dependent on detector type and environment
  • Noise Level
  • N/A (electronic panel)
  • Power Supply
  • 230V AC, 50Hz main supply
  • Remote Control
  • No
  • Sensitivity
  • As per connected detector type
  • Sensor Cable
  • 2-core, 1.5 sq.mm recommended
  • Sensor Life
  • Depends on detector; typically 5-10 years
  • Sensor Type
  • Compatible with conventional smoke & heat detectors
  • Standby Current
  • < 100mA (panel only)
  • Suitable For
  • Other, Small to medium commercial & industrial premises
  • Voltage
  • 24V DC (system circuitry)
  • Wireless
  • Other, No (conventional wired panel)
  • Working Current
  • ~150mA (alarm condition, panel only)

Ravel RE 102 Conventional Fire Alarm Control Panel

MOQ : 1 Unit

  • Alarm Density
  • One alarm per zone (multiple sensors per zone possible)
  • Alarm Light Color
  • Red (on panel indication)
  • Alarm startup time
  • <3 seconds (detection to indication)
  • Alarm time
  • Continuous till reset
  • Control Distance
  • As per wiring; each zone supports conventional wiring up to recommended limits
  • Detection Range
  • Depends on connected detectors, typically up to 100m per zone with standard detectors
  • Noise Level
  • Panel <30 dB (acoustic alarms external)
  • Power Supply
  • 230V AC 15%, 50 Hz
  • Remote Control
  • Other, No (Front panel operation only)
  • Sensitivity
  • Based on detector specifications (panel monitors detectors)
  • Sensor Cable
  • Suitable for 1.5 mm2 FRLS (max length per zone subject to voltage drop limits)
  • Sensor Life
  • Depends on detector type; typically 5-10 years
  • Sensor Type
  • Supports conventional smoke/heat detectors
  • Standby Current
  • <100mA (without alarm)
  • Suitable For
  • Other, Small/medium residential, office, commercial premises
  • Voltage
  • 24V DC operating (from inbuilt SMPS)
  • Wireless
  • Other, No (fully wired system)
  • Wireless Distance
  • Not applicable (wired system)
  • Working Current
  • Up to 200mA (with active alarms)

Addressable Ravel Moniti NX Fire Alarm System

MOQ : 1 Unit

  • Alarm Density
  • Varies by device and configuration
  • Alarm Light Color
  • Red (visual indicators on connected devices)
  • Alarm startup time
  • < 5 seconds (to first notification)
  • Alarm time
  • Continuous until reset or fault cleared
  • Control Distance
  • Loop-based, up to 2 km per loop
  • Detection Range
  • Up to 2000 meters (loop length dependent)
  • Noise Level
  • < 30 dB (panel operation)
  • Power Supply
  • 230V AC, 50Hz with backup battery support
  • Remote Control
  • Other, Supported via panel interface and optional modules
  • Sensitivity
  • Adjustable as per sensor type (with panel settings)
  • Sensor Cable
  • Twisted pair, shielded (as per installation standard)
  • Sensor Life
  • Typical 8 to 10 years (sensor dependent)
  • Sensor Type
  • Addressable smoke, heat, multi-criteria detectors
  • Standby Current
  • Less than 200mA
  • Suitable For
  • Other, Commercial buildings, institutions, industrial complexes
  • Voltage
  • 24V DC (internal electronics)
  • Wireless
  • Other, No (wired addressable system)
  • Wireless Distance
  • Not applicable (wired system)
  • Working Current
  • 400-600mA

Avni Lcs Ravel Loop Card

MOQ : 1 Unit

  • Alarm Density
  • High (up to industrial standards)
  • Alarm Light Color
  • Red
  • Alarm startup time
  • <1 second
  • Alarm time
  • Configurable
  • Control Distance
  • Up to 100 meters
  • Detection Range
  • Up to 6 meters
  • Noise Level
  • <70dB
  • Power Supply
  • 12V DC
  • Remote Control
  • Other, Supported
  • Sensitivity
  • Adjustable
  • Sensor Cable
  • Compatible with standard loop wire
  • Sensor Life
  • >5 years
  • Sensor Type
  • Electronic Loop Sensor
  • Standby Current
  • <25mA
  • Suitable For
  • Other, Vehicle detection, automatic gates, traffic control, parking management
  • Voltage
  • 12V-24V DC
  • Wireless
  • NO
  • Working Current
  • <50mA


Back to top