Conventional Fire Alarm Control Panel
Conventional Fire Alarm Control Panel

Conventional Fire Alarm Control Panel

Price 5000 INR/ Number

MOQ : 1 Number

Conventional Fire Alarm Control Panel Specification

  • Sensitivity
  • Based on detector specifications (panel monitors detectors)
  • Sensor Type
  • Supports conventional smoke/heat detectors
  • Voltage
  • 24V DC operating (from inbuilt SMPS)
  • Standby Current
  • <100mA (without alarm)
  • Working Current
  • Up to 200mA (with active alarms)
  • Suitable For
  • Small/medium residential, office, commercial premises
  • Alarm startup time
  • <3 seconds (detection to indication)
  • Alarm time
  • Continuous till reset
  • Alarm Density
  • One alarm per zone (multiple sensors per zone possible)
  • Sensor Cable
  • Suitable for 1.5 mm2 FRLS (max length per zone subject to voltage drop limits)
  • Control Distance
  • As per wiring; each zone supports conventional wiring up to recommended limits
  • Noise Level
  • Panel <30 dB (acoustic alarms external)
  • Wireless
  • No (fully wired system)
  • Sensor Life
  • Depends on detector type; typically 5-10 years
  • Wireless Distance
  • Not applicable (wired system)
  • Power Supply
  • 230V AC 15%, 50 Hz
  • Alarm Light Color
  • Red (on panel indication)
  • Remote Control
  • No (Front panel operation only)
  • Detection Range
  • Depends on connected detectors, typically up to 100m per zone with standard detectors
  • Number of Zones
  • 2 zones
  • Zone End of Line
  • 4k7 Ohm resistor
  • Display
  • LED indications for alarm, fault, power
  • Battery Backup
  • Provision for 2 x 12V sealed lead acid batteries (up to 7 Ah)
  • Weight
  • Approx. 5 kg (without batteries)
  • Cable Entry
  • Knockouts provided for cable entry
  • Panel Type
  • Conventional Fire Alarm Panel
  • Humidity
  • 0-95% RH (non-condensing)
  • Operating Temperature
  • 0C to +50C
  • Output Relays
  • Common Alarm, Fault & Supervisory relay outputs
  • Enclosure
  • Metal cabinet, wall mount
  • Controls
  • Mute, Reset, Test, Lamp Test buttons
  • Dimensions
  • Approx. 330 x 260 x 100 mm
 

Conventional Fire Alarm Control Panel Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About Conventional Fire Alarm Control Panel



Buy Online the Virtuoso  Conventional Fire Alarm Control Panel and experience unmatchable safety for your premises. This phenomenal  panel features rapid LED indications for alarm, fault, and power, combined with user-friendly controls like Mute, Reset, and Test functions accessible exclusively from the front panel. The metal enclosure ensures robust durability and easy wall mounting, while provision for battery backup keeps you protected during power outages. Access standard smoke/heat detectors, enjoy effortless cable management, and benefit from the lowest price deals online. Ideal for service providers, suppliers, traders, and all small to medium businesses in India.

Smart Protection for Every Space

The Conventional Fire Alarm Control Panel is specially crafted for small to medium residential, office, and commercial premises. Featuring dedicated zones for enhanced area coverage, its front panel offers straightforward operation with Mute, Reset, Test, and Lamp Test buttons. Brilliant LED indicators instantly alert you to any alarm, fault, or power status. This control panel supports conventional smoke and heat detectors, making it suitable for a wide range of fire safety applications.


Seamless Access and Service Offers

Sample availability for the  ensures you can evaluate before committing to a major outlay. Our flexible payment terms and reliable supply ability bring you peace of mind. Intrastate or interstate, we arrange swift freight so your order reaches on time. Whether you're looking for a single unit or bulk offer, rest assured of consistent quality, prompt delivery, and supportive customer service throughout the process.


FAQ's of Conventional Fire Alarm Control Panel:


Q: How many zones does the  fire alarm panel support?

A: The  supports two separate detection zones, allowing you to monitor multiple areas independently within your premises.

Q: What special features does this fire alarm control panel offer?

A: It is equipped with LED alarm, fault, and power indicators, front panel operation controls (Mute, Reset, Test, Lamp Test), and provides relay outputs for alarm, fault, and supervisory signals.

Q: Where is the  most suitably used?

A: This panel is ideal for small and medium-sized residences, offices, and commercial spaces looking for robust and reliable conventional fire detection solutions.

Q: What is the process of installing the fire alarm panel?

A: Installation involves wall mounting the metal cabinet, connecting the power supply and battery backup, wiring the smoke or heat detectors, and setting up end-of-line resistors for each zone.

Q: What are the benefits of using this fire alarm panel?

A: The offers quick alarm response, simple operation, durable construction, and adaptability with standard detectors, ensuring effective safety management at the lowest possible outlay.

Q: How does the panel alert users during an alarm condition?

A: Bright red LED indicators and relay outputs notify users immediately. The alarm lasts until it is manually reset from the front panel, ensuring prompt attention to any incident.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Alarm System Category

Addressable Multi Sensor Smoke Detector

Addressable Multi Sensor Smoke Detector

Price 1490.00 INR / Piece

Minimum Order Quantity : 5 Pieces

Voltage : 15V to 30V DC

 Fire Alarm Panel

Fire Alarm Panel

Minimum Order Quantity : 1 Unit

Voltage : 24V DC (system circuitry)

Sensor Type : Compatible with conventional smoke & heat detectors

Control Distance : Varies as per installation specifications

Wireless : Other, No (conventional wired panel)

Addressable Ravel Moniti NX Fire Alarm System

Addressable Ravel Moniti NX Fire Alarm System

Minimum Order Quantity : 1 Unit

Voltage : 24V DC (internal electronics)

Sensor Type : Addressable smoke, heat, multicriteria detectors

Control Distance : Loopbased, up to 2 km per loop

Wireless : Other, No (wired addressable system)

Avni Lcs Ravel Loop Card

Avni Lcs Ravel Loop Card

Minimum Order Quantity : 1 Unit

Voltage : 12V24V DC

Sensor Type : Electronic Loop Sensor

Control Distance : Up to 100 meters

Wireless : NO



Back to top