Gas Suppression System
Gas Suppression System

Gas Suppression System

MOQ : 1 Unit

Gas Suppression System Specification

  • Fire Class
  • Class A (solids), Class B (flammable liquids), Class C (electrical fires)
  • Mounting Type
  • Fixed, modular banked cylinders
  • Voltage
  • 24 V DC (control panel supply)
  • Fire Extinguisher Type
  • Clean agent gaseous extinguisher (FM-200, Novec 1230, Inergen, CO2)
  • Features
  • Non-corrosive, rapid discharge, minimal residue, ozone-friendly, safe for electronics
  • Coating Type
  • Corrosion-resistant powder coating
  • Working Temperature
  • Typically -20C to 55C
  • Technology
  • Clean agent gaseous fire suppression with automatic detection and control
  • Shape
  • Cylindrical
  • Control Type
  • Automatic and manual activation through control panels
  • Operating Pressure
  • Consistent with storage pressure, 25 bar or 42 bar
  • Coverage Area
  • Scalable system, typically covers 100 m2 up to 2500 m2 or more
  • Connectivity Type
  • Integrated with fire detection and building management systems
  • Installation Type
  • Fixed, wall-mounted or floor-standing modular installation
  • Energy Efficiency Rating
  • Not applicable (no continuous energy use)
  • Application
  • Server rooms, data centers, control rooms, electrical cabinets, communication facilities, archives, and storage areas
  • Max Flow Rate
  • Designed for fast agent discharge within 10 seconds
  • Diameter
  • Standard cylinder diameter typically ranges from 180 mm to 250 mm depending on capacity
  • Capacity
  • Varies per cylinder, common sizes are 40L, 67L, 80L, 100L, and more
  • Pressure
  • Storage pressure typically 25 bar or 42 bar (varies by gas used)
  • Detection Compatibility
  • Compatible with smoke, heat, and manual detection systems
  • Noise Level
  • Silent operation during standby, minimal noise during discharge
  • Compliance Standard
  • Conforms to NFPA 2001/ISO 14520 and local fire authority guidelines
  • System Lifespan
  • Typically over 15 years with periodic maintenance
  • Agent Release Time
  • Less than 10 seconds for total flooding
  • Refillable
  • Yes, after discharge or maintenance
  • Application Method
  • Total flooding and local application methods supported
  • End-of-Line Monitoring
  • Integrated for circuit integrity
  • Discharge Nozzles
  • Precision multi-directional nozzles for complete coverage
  • Cylinder Quantity
  • Expandable-system can bank multiple cylinders as required for area
  • Color
  • Red with coded color bands for agent identification
  • Cylinder Material
  • High-strength alloy steel
 

Gas Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

More Products in Fire Fighting Equipment Category

Fire Hydrant System

Fire Hydrant System

Minimum Order Quantity : 1 Unit

Fire Class : Class A, B, C fires

Application : Fire safety protection in commercial, industrial, and residential buildings

Mounting Type : Floor/wall mounting for hydrant outlets

Technology : Wet riser, external hydrant line, automatic/manual operation

Shape : Cylindrical/horizontal & vertical pipe runs